제품소개
view
OPE-QI Series Linear Programmable DC Power Supply
OPE-QI Series is high performance programmable DC power supply with RS232C or RS485 interface based on SCPI (Standard Commands for Programmable Instruments) protocol and the combination of bench-top and system features in these power supplies provides versatile solutions for your design and test requirements in the industrial fields, R&D institute center and education fields.
Dimension
19inch half x 2U size : 213mm(W) x 88mm(H) x 362mm(D)-
1 LCD (Volt/Curr Message Display module) 13 Fixed 1 Over Load Protection Lamp 2 Encoder S/W for changing Volt/Curr 14 Fixed 2 Over Load Protection Lamp 3 I/O or LOCAL Key 15 Fixed 1 & Fixed 2 Voltage selection switch 4 Ouput ON/OFF Key 16 Fixed 1(5V/2A & 3.3V/2A) + output terminal 5 Volt/Curr select or Limit Display Key 17 Fixed 1(5V/2A & 3.3V/2A) – ouput terminal 6 OUTPUT channel SELECT or Tracking Key 18 Fixed 2(15V/1A & 12V/1A) + ouput terminal 7 Volt/Curr Cursor or menu change Key 19 Fixed 2(15V/1A & 12V/1A) – ouput terminal 8 Volt/Curr Cursor or menu change Key 20 P1 Output Terminal (Positive Output) 9 P1 Constant Current mode indicate Lamp 21 P1 Output Terminal (Negative Output) 10 P2 Constant Current mode indicate Lamp 22 P2 Output Terminal (Positive Output) 11 P1,P2 channel Tracking mode indicate Lamp 23 P2 Output Terminal (Negative Output) 12 Remote Interface mode indicate Lamp 24 Main Power ON/OFF Switch - 3-Digit Display Resolution
- 16×2 Big-Character Type LCD Display
- CV/CC Mode
- Output ON/OFF Function
- Tracking Mode Function(Control 2 output at the same time)
- 2 variable output & 2 fixed output
- Memory Save and Recall(Up to 5 operation states)
- Half of 19inch(213mm) wide x 2U size(Less than 300W)
- RS-232C communication interface(RS-485 is optional)
-
-
TRACKING MODE
- Two channels can be controlled at once.
If single channel power supply was supplied for each producer when it comes to your company’s mass production system, replace it with the power supply in two channels that supports our company’s tracking mode!
There is no need to set up two channels’ voltage and current which is cumbersome.
Instead, pressing simply one button, the tracking mode button can set up two channels in the same way using only one setting for the voltage, current and all the functions.
-
-
-
STORE & RECALL
- Save and Recall Voltage and Current set by user easily
OPE Series can store and recall the voltage and current set by user.
Even when a user is not an engineer, the user can use it easily for the production, product inspection, reliability test etc., with the Store and Recall function that set up and stored in advance.
-
제품라인업 및 사양
Model
ParameterOPE-185QI
OPE-303QI
OPE-305QI
OPE-503QI
Output rating 0~±18V, 0~5A 2CH
Fixed output 2CH0~±30V, 0~3A 2CH
Fixed output 2CH0~±30V, 0~5A 2CH
Fixed output 2CH0~±50V, 0~3A 2CH
Fixed output 2CHResolution
Programming/Readback
≤ 6mV / ≤ 1.5mA
≤ 7.5mV / ≤ 1mA
≤ 7.5mV / ≤ 1.5mA
≤ 15mV / ≤ 1mA
Display Meter
100mV / 10mA
100mV / 10mA
100mV / 10mA
100mV / 10mA
Programming Accuracy (@25℃ ±5℃)±(%of output + offset)
Voltage
0.2% + 120mV
0.2% + 200mV
0.2% + 200mV
0.2% + 300mV
Current
0.2% + 25mA
0.2% + 15mA
0.2% + 25mA
0.2% + 15mA
Read-back Accuracy (@25℃ ±5℃)±(%of output + offset)
Voltage
0.2% + 120mV
0.2% + 200mV
0.2% + 200mV
0.2% + 300mV
Current
0.2% + 25mA
0.2% + 15mA
0.2% + 25mA
0.2% + 15mA
Ripple & Noise
≤ 2mVp-p, ≤ 2mArms
≤ 2mVp-p, ≤ 2mArms
≤ 2mVp-p, ≤ 2mArms
≤ 3mVp-p, ≤ 2mArms
Voltage Programming Speed(No load)
Rising time
≤ 40㎳
≤ 40㎳
≤ 40㎳
≤ 70㎳
Falling time
≤1.2s
≤1.2s
≤1.2s
≤1.5s
Model
ParameterOPE-801QI
OPE-1001QI
OPE-1201QI
Output rating 0~±80V, 0~2A 2CH
Fixed output 2CH0~±100V, 0~1A 2CH
Fixed output 2CH0~±120V, 0~1A 2CH
Fixed output 2CHResolution
Programming/Readback
≤ 30mV / ≤ 0.8mA
≤ 40mV / ≤ 0.5mA
≤ 50mV / ≤ 0.5mA
Display Meter
100mV / 10mA
1V / 10mA
1V / 10mA
Programming Accuracy (@25℃ ±5℃)±(%of output + offset)
Voltage
0.3% + 500mV
0.5% + 800mV
0.5% + 900mV
Current
0.2% + 15mA
0.2% + 15mA
0.2% + 15mA
Read-back Accuracy (@25℃ ±5℃)±(%of output + offset)
Voltage
0.3% + 500mV
0.5% + 800mV
0.5% + 900mV
Current
0.2% + 15mA
0.2% + 15mA
0.2% + 15mA
Ripple & Noise
≤ 6mVp-p, ≤ 2mArms
≤ 0.01%mVrms, ≤ 2mArms
≤ 0.01%mVrms, ≤ 2mArms
Voltage Programming Speed(No load)
Rising time
≤ 70㎳
≤ 70㎳
≤ 70㎳
Falling time
≤1.5s
≤1.5s
≤1.5s
Common Details 2Fixed output channels(5V or 3.3V& 2A / 15V or 12V & 1A)
Half of 19inch x 2U size: 213mm(W) x 88mm(H) x 362mm(D), RS-232C interface-
옵션
- RS-232C cable
- RS-485 cable
- OVP, OCP(Remote Communication control only)
- Output ON/OFF signal control
- Analog Programming(Vout & Iout voltage programming) & Monitoring(Output Voltage & Current Monitoring) by 0~5V or 0~10V, Isolated type
- AC Power Cord(Other type)
- AC Input 110V ± 10%, 230V± 10%, 50~60Hz
- Rack Mount Support(Bracket and Shelf)
-
액세서리
- AC Power Cord(Type F)
- Operating Manual(QR Code)
- Demo software program(QR Code)
- Banana to Alligator DC Output Cables(+,-)
-
-